Field of Application

The "Capatect Schraubdübel Easy 051" consists of the dowel shaft Ø 8 mm, with pre-mounted, glass fiber reinforced plastic screw and dowel plate Ø 60 mm. The dowel plate is arranged flush on the insulation surface during installation.

Approved fixing for Capatect facade insulation boards within Capatect facade systems in suitable substrates. For insulation thicknesses from 60 mm in surface-flush installation.

Material Properties

  • Low anchorage depth in all use categories (A - E)
  • thermal bridge optimized = Chi value 0.000 W/K
  • for mounting flush with the surface
  • time-saving processing
  • secure setting control and anchoring in all common substructures

Colours

Carbon color

Storage

Cool, dry and frost protected.

Technical Data

approvalProduct-No.Length
(mm)
Anchorage
depth
hnom (mm)
Packaging
(units/box)
Capatect
Schraubdübel Easy 051


European Technical Approval:
ETA-16/0970

Use category according to ETA,
i. e. for wall building materials:

A = concrete
B = solid bricks
C = perforated bricks
D = lightweight aggregated concrete
E = autoclaved aerated concrete

Weather shell ≥ 40 mm und < 100 mm
051/100100≥ 30100
051/120120≥ 30100
051/140140≥ 30100
051/160160≥ 30100
051/180180≥ 30100
051/200200≥ 30100
051/220220≥ 3050
051/240240≥ 3050
051/260260≥ 3050
051/280280≥ 3050
 051/300 300≥ 3050






















In Use Category E, higher tensile capacities are required at greater anchorage depths (≥ 50 mm).

Supplementary Product

When installing "Capatect MW-Fassadendämmplatte 149 EXTRA, 151 EXTRA and 159 FKD-T C2" use Ø 90 mm and for "Capatect LS-Fassadendämmplatt VB 101" use Ø 140 mm "Dübelscheibe Easy".

Dowel plate color: White
Prod.-No.                Plate-Ø           
153/Easy140   140 mm     
153/Easy9090 mm







Dowel accessories:

Product name
Produkt-No. 
Packaging 
(units/box)
Capatect Schraubdübel Tool Easy 051/02
for surface flush mounting

consisting of:
- 1 Setting tool
- 1 Bit Torx T30
051/021

Product No.

051

Substrate Preparation

Ensure that the insulation boards are laid flat and that the edges are glued correctly.
The dowel length must be determined depending on the anchoring base, if necessary take any non-load-bearing layers and the system thickness into account.

Installation

The dowels should be installed only after sufficient solidification of the adhesive bed (approx. 1 day). The dowel length must be selected in such a way that the anchorage depth of at least 30 mm ( aerated concrete at least 50 mm) in the solid wall material is given (without taking into account any old render layers or other non-load-bearing intermediate layers). Use a drilling machine (for vertically perforated bricks, sand-lime bricks and aerated concrete without percussion and hammering action) to drill the dowel holes Ø 8 mm, at right angles into the load-bearing structural member. Always drill about 10 mm deeper than the required clamping depth. Before inserting the dowel, remove drill dust from the drill hole to ensure the required anchorage depth.

Surface flush mounting:
Drill a hole through the insulation material into the load-bearing substrate. Drill hole depth for substrates of category A-E min. 40 mm at 30 mm anchorage depth. In substrate category E, drill hole depth min. 60 mm at 50 mm anchorage depth.

Combine dowels and dowel plates depending on the type of insulation material. Insert the screw dowel into the drill hole and screw in the corresponding bit or tool so that it is flush with the surface. The dowel plate must lie flush with the surface after the setting process.

Dowel length determination:
La > hnom+ ttol+ hD
La = Dowel length
hnom = necessary anchoring depth
ttol = Tolerance compensation (thickness of adhesive layer) and, if necessary, non-bearing
Building component layers
hD = Insulation thickness

Approval

ETA-16/0970

Customer Service Centre

Tel.: +49 6154 71-71710
Fax: +49 6154 71-71711
e-mail: kundenservicecenter@caparol.de

International Distribution: Please see www.caparol.com

Technical information